Alert on PST Cylinder, LLC / DOT SP Permit Renewal

GAFSED • December 14, 2022
NAFED

Dear Member:
 
Back on October 19, 2022, an alert pertaining to the expiration of PST Cylinders, LLC DOT SP-9791 certification was issued.
 
We received notice from G3 Industries Inc., parent company of PST, that DOT SP-9791 has been renewed. The new expiration date is November 30, 2026. Attached is a copy of the approved permit renewal for SP-9791 for your records/file.
 
Regards,
Dave P.

Approved Permit Renewal
NOTICE OF ENFORCEMENT DISCRETION REGARDING CYLINDERS THAT HAVE EXCEEDED THEIR PERIODIC REQUALIFICATI
By GAFSED October 11, 2024
The U.S. Department of Transportation’s Pipeline and Hazardous Materials Safety Administration (PHMSA) understands that due to the flooding and damage caused by Hurricane Helene, many members of the medical and industrial gas industry may be experiencing difficulty in obtaining cylinders due to the increased demand for these gases or a disruption in the normal business model for cylinder exchange and testing facilities.
A fire extinguisher is attached to a map of georgia.
By GAFSED October 11, 2024
Portable fire extinguishers and fire extinguisher system components may be serviced by companies not located in this state, when a company licensed by the Safety Fire Division has placed their own tag upon that extinguisher.
lithium-ion batteries
By GAFSED October 3, 2024
As the prevalence of lithium-ion batteries in our daily environment continues to increase, so does the need for a fire protection solution. To capitalize on this growing market, several companies have introduced fire extinguishers to the marketplace that claim to address the multiple hazards associated with lithium-ion thermal runaway/fire events.
NFPA 96 2017 Edition
By GAFSED March 26, 2024
NFPA 96 2017 Edition, the currently adopted edition which does not change in the latest edition published by NFPA, requires that at minimum there be an audible OR visible indicator to show that the system has activated. In 10.6.2 it requires that IF the building has a fire alarm system the activation of the extinguishing system shall activate the building fire alarm system.
The Dalton Fire Department is warning residents of a recent scam circling the community.
By GAFSED August 21, 2023
REMINDER: The Dalton Fire Department does not use third-party companies to perform fire safety inspections or any other services on behalf of the DFD. Earlier this year we told you about a fire extingusiher service company from out of town has been contacting local businesses in our area and using pushy sales tactics to suggest that they are offering fire inspections at the direction of the DFD but this is *not* the case.
Update: ANSUL CLEANGUARD Fire Extinguisher DOT Requirements
By GAFSED June 30, 2023
This Special Report updates a communication from back in March 2023. On May 23, 2023, the US Department of Transportation (USDOT) issued a revision to Special Permit (SP) DOT-SP 21502 for transportation of ANSUL CLEANGUARD fire extinguishers. The revision is the result of a DOT PHMSA editorial review of the Special Permit with intent to provide additional clarity.
Elimination of CO2 Cartridges for use in Restaurant Systems
By GAFSED April 24, 2023
As part of our improved delivery initiatives, we are continuing to review all components offered for sale. To assist with production efficiency and reduced lead times we will be discontinuing the offering of CO2 cartridges for use in restaurant systems, effective May 1st, 2023. T he impacted part numbers are listed below with the applicable Nitrogen Cartridge replacement.
Reminder: The Norb Makowka Award
By GAFSED March 20, 2023
This year, NAFED is introducing The Norb Makowka Award. This annual award honors a technician in the fire protection industry who has put their energy and time into embracing codes and standards, working towards improving their knowledge and understanding in the fire protection industry, and investing time improving our industry through organizations, committees, and related associations.
Foam Extinguisher Agent and Recharge Disposal
By GAFSED March 16, 2023
The intent of this special report is to address the disposal of pre-mixed foam solutions utilized in foam extinguishers. Fluorinated Class B firefighting foam has played an important role in the protection of flammable and combustible liquid risks over many decades.
Alert on Expired DOT Permit
By GAFSED October 19, 2022
It has been brought to NAFED’s attention that the DOT Special Permit (SP-9791) issued in the name of PST Cylinders expired on September 30, 2022. Please note PST Cylinders, LLC, is now under the ownership of G3 Industries in Kronenwetter, Wisconsin. (G3 Industries - Pressed Steel Tanks)
More Posts
Share by: